Natural Draft Cooling Tower

We are involved in offering a comprehensive range of Natural Draft Cooling Towers, which doesn’t require any fan, or PVC fills for operation. These are 100% safe and works efficiently without any power or maintenance like other towers. The aerodynamic design and FRP louvers provided reduce spillage and evaporation loss. These are also equipped with hat dip galvanized structural and S.S. fasteners which ensures durability and efficiency of these tower. Our range of natural draft cooling towers can be installed with any type of cooling application. In addition the non-clog nozzles fitted in the tower are easy to clean. We offer these towers at very affordable price and even offer some spare nozzle with this tower.

Features of Natural Draft Cooling Tower
  • No requirement Fan, Motor and PVC fills.
  • Power saving (no power consumption to induce air flow- no fan)
  • Low maintenance
  • FRP louvers reduces spillage and evaporation loss
  • Hot Dip galvanized structure and S.S fasteners increase the life time and efficiency of cooling tower
  • Can be installed for any range of cooling applications
  • Non clog nozzles
  • Easy to clean
  • Environmental Friendly
  • No Mechanical Noise
  • Safety of operation

The Natural draft cooling towersare particularly pretty as a cost-saving solution for power plants and other industrial plants requiring larger quantities of cooling water. Natural Draft cooling tower operates without fans and Fills, the large amount of electric power or else required for large cooling tower systems is not required. The mandatory cooling air is pass on through the tower by natural draft henceforth neither fan nor fan power is required for these kind of Cooling Solution. No maintenance required like other Wet (or) Dry Cooling Towers. By using of Non clock nozzle are easy to cleaning reqduce spillage and evaporation loss. Hot Dipped Galvanized Structural’s and S.S.fasteners increase the lifetime as well as the efficiency of the cooling tower it can be installed for any range of cooling application.

Structure : Is made from heavy M.S.Angle/Tee/Channel sections and Hot Dipped Galvanised or lined with FRP for corrosion resistance.

Louvers : Are made from Fiberglass Reinforced Plastics which ensures corrosion resistance and good mechanical properties.

Water Distribution Headers : Are made from “c” class galvanised pipe.

Nozzles : Are made from Rigid PVC (or) Brass Nozzle to give good corrosion resistance.

Nuts and Bolts : Are made from Stainless Steel (or) HDG Bolt and Nuts.

Features and Functions of Natural Draft Cooling Towers

Natural Draft Cooling Tower especially hold attraction as solution for saving costs for large industrial plants and power stations; that require large amounts of cooling water.

The needed cooling air is transported to the tower with the help of natural draft. Hence there is no necessity for fan or fan power. It is also used for the release of treated exhaust gas. It also implies that there is no need of gas reheating or chimney. PVC Fills, motor, fan are not required by Natural Draft Cooling Towers. FRP Louvers that are specially designed aerodynamically, minimize evaporation loss and spillage.